Leave Your Message
  • Xov tooj
  • E-mail
  • Wechat
    Wechat
  • WhatsApp
  • Facebook
  • linkedin
  • Fluke 376 FC True-RMS Clamp Meter nrog iFlex
    Fluke 376 FC True-RMS Clamp Meter nrog iFlex

    Fluke 376 FC True-RMS Clamp Meter nrog iFlex

    Cov yam ntxwv tseem ceeb:

    ● Ntsuas AC / DC tam sim no nrog iFlex tam sim no soj ntsuam.

    ● VFD low pass lim rau qhov tseeb ntsuas ntawm cov teeb liab tsis-linear.

    ● Tej thaj chaw deb teev, sib txawv thiab saib xyuas kom paub meej qhov tsis sib xws.

    ● Inrush ntsuas los lim tawm suab nrov thiab ntes pib tam sim no.

      Cov khoom muag

      Fluke 376 FC True-rms Clamp Meter nrog iFlex yog qhov kev daws teeb meem zoo tshaj plaws rau cov neeg siv hluav taws xob thiab kev lag luam. Lub 376 yog ib feem ntawm Fluke Connect tsev neeg ntawm cov cuab yeej kuaj wireless uas ua rau koj nkag mus, sib txawv thiab saib xyuas kev ntsuas thaum tseem nyob nyab xeeb ntawm thaj tsam arc flash los ntawm kev sib txuas Bluetooth.

      Nrhiav qhov ua rau muaj teeb meem nyuaj
      Lub 376 FC clamp meter siv ib qho kev sib xyaw ua ke uas tsis tshua muaj lim rau kev ntsuas qhov tseeb ntawm cov teeb liab tsis-linear, xws li hloov tau ceev tsav, hluav taws xob ballasts thiab lwm yam tsis-linear loads. Lub clamp kuj tseem siv cov cuab yeej ntsuas kev ntsuas cov cuab yeej los lim tawm suab nrov thiab ntes lub cev muaj zog pib tam sim no raws nraim li kev tiv thaiv Circuit Court pom nws.


      Ntsuas

      ● Voltage rau 1000 V AC lossis DC.

      ● Resistance rau 60 kΩ nrog kev tshawb nrhiav txuas ntxiv.

      ● Min, max, nruab nrab, thiab inrush kaw kom ntes cov kev hloov pauv tau.

      ● 500 mV DC ntsuas ntau rau kev cuam tshuam nrog lwm yam khoom siv.

      ● 1000 μF capacitance ntsuas.

      Khoom Paub meej

      ada1 (1)re3Fluke 376 FC True-RMS Clamp Meter nrog iFlex (2)f6j

      Ua haujlwm nyab xeeb thiab yooj yim

      Lub 376 FC clamp nqa CAT III 1000 V, CAT IV 600 V kev nyab xeeb ntsuas, tsim los muab kev tiv thaiv siab tshaj plaws rau koj hauv cov cuab yeej kuaj.
      Qhov suav nrog iFlex hloov pauv tam sim no kev sojntsuam muab kev nkag tau yooj yim dua rau cov neeg siv loj hauv qhov chaw nruj. Flexible sojntsuam:

      ● nthuav qhov ntsuas qhov ntsuas mus rau 2500 A AC.

      ● Tso cai ntsuas zaus mus rau 500 Hz nrog lub cev lub puab tsaig thiab iFlex.

      Dab tsi nyob hauv lub thawv

      ● Fluke 376 FC True-RMS Clamp Meter.

      ● 18-nti iFlex® Flexible Current Probe.

      ● TPAK hlau nplaum dai pluaj.

      ● TL75 Test Leads.

      ● Ob lub AA roj teeb (Nruab).

      ● Cov hnab nqa khoom mos.

      Cov khoom muaj feem xyuam