    The high performance differential pressure transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJA110E outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types,are certified as complying with SIL 2 for safety requirement.

      EJA110E key features

      ●0.055% Accuracy (0.04% Accuracy optional)

      ●0.1% Stability per 10 years

      ●90 ms Response Time

      ●Exida and TUV SIL 2 / SIL3 Certified

      ●MWP 2,300 psi (MWP 3,600 psi option)

      ●Local Parameter Setting (LPS)

      Digital Performance

      adfa2barRuggedC_EJX910A-EJA110Ezmq

      Yokogawa's DPharp digital sensor offers twice the performance and stability of the competitor's analog sensors. The DPharp uses the latest in IC Chip-style design and manufacturing technology. Analog sensors are based on older design technology. Although analog sensors are good, the modern DPharp sensor out performs them. A Yokogawa transmitter with DPharp digital sensor will give you the consistent, reliable, accurate measurement you need.

      Product Details

      an1lzoIMG_20170822_10050198van299s

      Accuracy Under All Operating Conditions

      Yokogawa's DPharp sensor has the ability to measure the differential pressure (DP), static pressure (SP), and sensor temperature from a single sensor. Giving these three pieces of process data, Yokogawa's transmitter can compensate the DP measurement for Temperature Effect and Static Pressure Effect in real time. This is referred to as Dynamic Compensation and improves the DP measurement accuracy.Competitor's analog sensors can only measure DP and Sensor temperature. So, theirs can compensate for temperature Effect; but, since the SP measurement is missing, it cannot compensate for Static Pressure Effects.